SLQ-82 Series Large Current Generator

SLQ-82 Series Large Current Generator

Classification: Partical Discharge/AC DC hipot test set

Reference standard: DL/T596-2005

Verification:  View the certificate

Instructions:  DOC Instructions

  PDF Instructions

Tel: 027-87207771 87207772 87207773 87188862

Verification certificate
Product introduction

SLQ-82 series large current generator is special designed and manufactured for power sector, industrial and mining enterprises electrical equipment testing. Suitable for a variety of switches, current transformers and other current loaded testing of electrical equipment, elevated temperature test.

Alternative name

boost converter, large current testing equipment, large current testing equipment

The Characteristics of the products

1, SLQ-82 series large current generator with two ammeter, large and small range monitor

2, The autotransformer adjustable

3, LED indication, button operation, simple to operate

4, Install by separated structures, easy to move

The parameters of the products

Type

Rated capacity(kVA)

boost converter rated input

boost converter rated output

Resistance voltage

Unload current

Structure

voltage regulator

boost converter

Current(A)

Voltage
(V)

Current
(KA)

Voltage
(V)

SLQ-82/500A

3

3

13.6

220

0.5

5

>8

>6

integrated

SLQ-82/1000A

5

5

22.7

220

0.5/1

10/5

>8

>6

integrated/Partial

SLQ-82/2000A

10

10

45.4

220

1/2

10/5

>8

>6

Partial

SLQ—82/4000A

20

20

50

400

2/4

10/5

>8

>6

Partial

SLQ—82/5000A

25

25

62.5

400

2.5/5

10/5

>8

>6

Partial

SLQ—82/10000

50

50

125

400

5/10

5

>8

>6

Partial

Note: In the column “booster rated output ”, the left is series output parameter, the right is parallel output parameter. Such as in the “0.5/1”, “0.5” means series output parameter; “1” means parallel output parameter.


Power supply: AC110V/115V/120V/127V/220V/230V/240V optional
Input frequency: 50Hz/60Hz optional
Note: The users can select the corresponding power which based on their local supply voltage and frequency, and we will confirm it before the delivery (or inform us that the goods will be used in which country advance)

Product information

a) SLQ-82 series large current generator is designed for short time working, so do not allow for a long time working under the rated capacity, in particular must not exceed the rated current running, in order to prevent overheating, the time range as follows:


Load condition(Rated point%)

Maximum lasting running time(min)

100

30

85

90

75

180

b) For the new installed and long time no using transformer, should use the 1500 megger to measure the coil and coil-to-ground insulation resistance before using, if the value of the resistor is not less than 0.5 megohms, it can be used.
c) In use, the boost transformer and operation desk must be grounded, to ensure safety.
d) The boost process should be slowly and evenly, in the process of movement, should avoid excessive vibration during moving .
e) The contact surfaces of regulator and electrical brush should be kept clean, depending on the circumstances, can use a 90% alcohol dipped cotton to wipe.
f) SLQ-82 series large current generator should be stored in a clean, ventilated and dry place.