NRBZC-Ⅲ Automatic Variable Ratio Group Tester

NRBZC-Ⅲ Automatic Variable Ratio Group Tester

Classification: Transformer Inspection/Switch Testing Device

Reference standard: DL/T963-2005

Verification:  View the certificate

Instructions:  DOC Instructions

  PDF Instructions

Tel: 027-87207771 87207772 87207773 87188862

Verification certificate
Product introduction

When using the radio bridge to measure the transformer ratio, the operation procedure is complex, the measuring measure range is narrow, which is no longer meet modern fast-paced, high-efficiency requirements. Therefore, NANR electrical uses the modern electronic technology, developed a new generation of automatic variable ratio group tester. It is small, light, high accuracy and with good stability. It uses a large-screen character display, menu operation, friendly interface. The variable group can measure at once. NRBZC-Ⅲ Automatic variable ratio group tester is ideal product for electrical industry department.

Alternative name

Transformer ratio group tester, transformer ratio tester, transformer ratio automatic tester, automatic transformer ratio tester, transformer ratio group testing device, transformer ratio testing device, transformer ratio automatic testing device.

The Characteristics of the products

1. Automatic measurement wiring group.

2. Automatic group transformation.

3. Automatic switching phase sequence.

4. Automatic shift ranging.

5. Automatic calibration.

6. Input the standard ratio, it can automatically calculate the relative error.

7.When the measurement is completed, it can cut off the testing voltage automatically .

8. Setting the data, the measured results can be saved automatically, and can be view the previous data.

9. Measuring loaded transformer ratio, only need to enter once

The parameters of the products

1. Ratio measuring range: 1-10000
2. Group:1-12:00

3. Accuracy: 1-1000  0.2 grade,1000-10000 0.5 grade

4. Power supply: AC220V ± 10%, 50HZ

5. Operating temperature: -5 ℃ ─ 40 ℃

6. Operating humidity: <85%

7. Volume: 430mm × 320mm × 215mm

8. Weight: 8Kg


Power supply: AC110V/115V/120V/127V/220V/230V/240V optional
Input frequency: 50Hz/60Hz optional
Note: The users can select the corresponding power which based on their local supply voltage and frequency, and we will confirm it before the delivery (or inform us that the goods will be used in which country advance)

Related products
Product information

Precautions
1.Insurance 1 is 2A, Insurance 2 is 0.5A. If the testing line is short-circuit , the high and low voltage will be reversed, will burn the fuse. Once fused, it will be displayed " measuring , wait ! " and then stop to operate and cut off the power.. Please replace the same capacity insurance, then retesting .

2.Maintain the connections is fine. The instrument should be well grounded !

3.Ensure the workplace keep away from strong electric field , magnetic field and high-frequency devices. Power supply interference should be the smaller the better, and use light line. If the power supply interference is still large, it better to use the AC purified power,.the purified AC power supply capacity just larger than 200VA will do.

4.During the operating, if there is disorder on LCD screen, and without any response after press all the button, or the measured value is much very far away from the actual value, please press the reset button, or turn off the power, then restart the operate .

5.If the displays without character display ,or the color is weak, please adjust the brightness potentiometer to the appropriate location . Brightness potentiometer is a multi-turn potentiometer with 10 laps !
6.The instrument should be stored in dry and ventilated place , if unused for a  long-term, or stored in a humid environment, it need to extend the warm-up time before using , to remove  the moisture.
7.Communication port used for debugging .