SMG2000 Series Digital Display Clamp-on Phase Meter

SMG2000 Series Digital Display Clamp-on Phase Meter

Classification: Measurement Product/Secondary Circuit Test

Reference standard: JJG440-2008

Verification:  View the certificate

Instructions:  DOC Instructions

  PDF Instructions

Tel: 027-87207771 87207772 87207773 87188862

Verification certificate
Product introduction

SMG2000 series Digital Display Clamp-on Phase Meter is special designed for voltage, current and phase tests, it is in high-precision, low price, portable hand-held, dual-channel input measuring. It's easy to measure the phase between U-U, I-I and U-I, identify the inductive circuit ,capacitive circuit and the phase sequence of three-phase voltage, detect the wiring group of transformer, test the secondary circuit and bus differential protection system, display the phase relationship among the CT groups of a differential protection system, and check if the wire of electric meter was correctly connected. When testing customers do not need cut off the tested current which input by slip core current transformer. When measuring the phase between U1 and U2, the two input circuit loop are completely isolated, so the possible misconnection is absolutely avoided, which may result in short circuit and may even burn the meter. The monitor of the device is high-contrast LCD screen, and the character in which could be as high as 25mm, and can be freely rotated approximately 70 °, which helps to obtain the best visual effects.

    The shell of the device is made of engineering insulating material, together with a rubber–made anti-vibration protection kits for safety and reliability.
Alternative name

Phase meter, clamp phase meter, digital clamp phase meter

The Characteristics of the products
1. Withstand Voltage
Parts between voltage input terminal and meter shell, parts between the iron core of the clamp-current transformer and secondary windings can stand 1000V/50Hz. Parts between the two voltage input terminals can stand Sinusoidal AC Voltage 500V/50Hz for 1min when testing.
2. Insulation Resistance
Between meter circuit and meter shell, between the two voltage input terminals:≥10MΩ
The parameters of the products

1.Reference operating conditions

Temperature
(23±5)℃
Humidity
(45~75)% RH
Wave forms of measured signal
sine wave β=0.02
Frequency of measured signal
(50 ± 0.2) Hz
Position of measured current carrying conductor in the nipper jaw
optional position
Amplitude range of measured signal when measuring phase
100~220V, 0.5A~1.5A
External reference frequency electromagnetic interference
Should be avoided

2.The limits of intrinsic error

Model

Specification

SMG-2000B

SMG-2000E

Measuring error
 of AC voltage

Range

20V
200V
500V
20V
200V
500V

Resolution

0.01
0.1
1
0.01
0.1
01

Error limit

±(1.2%RD+2)

±(1.0%RD+2)

±(1.2%RD+2)

±(0.3% RD + 0.2% range)

Input impedence

all the measure range is 2MΩ

all the measure range is 2MΩ;When measuring phase, the input impedance of voltage terminal > 500KΩ

Measuring error
 of AC current

Range

200mA
2A
10A
200mA
2A
10A

Resolution

0.1mA
1mA
10mA
0.1mA
1mA
10mA

Error limit

± (1.0%RD + 2)

±(0.3% RD + 0.2% range)

Error of Power-frequency Phase

Range

0~360°

Resolution

Error limit

±3°

±2°

3.Operating error
① Rated Operating conditions

Temperature

(0 ~ 40)℃

Humidity

(20 ~ 80)% RH

Wave forms of measured signal

sine wave β=0.05

Frequency of measured signal

(50 ± 0.5) Hz

Position of measured current carrying conductor in the nipper jaw

optional position

Amplitude range of measured signal when measuring phase

Phase U1-U2

30V~500V

Phase I1-I2

10mA~10.00A

Phase U1-I2 or I1-U2

10V~500V, 10mA~10.00A

External reference frequency electromagnetic interference

Should be avoided

② Limits of rated operating error
Under the conditions described in 3.3.1, the limits of rated operating error will not exceed twice of the limits of intrinsic error.

4. Other technical parameters:

Specification

Model

SMG-2000B

SMG-2000E

Display

three and half digital

Sampling rate

3 times/ seconds

Power supply

9V single laminated batteries, the supply current <5mA.

The size of meter

190mm×95mm×55mm

186mm×86mm×33mm

The size of clamp

140mm×42mm×20mm

140mm×40mm×19mm

The size of jaws

Φ7mm×9mm

Φ7mm×8mm

The weight of meter

280g

280g

The weight of clamp

2×200g

2×200g

The conditions of storage