SMG3000/SMG3010 Handheld Three-phase Volt-ampere Meter

SMG3000/SMG3010  Handheld Three-phase Volt-ampere Meter

Classification: Measurement Product/Secondary Circuit Test

Reference standard: GB/T13978-2008,DL/T980-2005

Verification:  View the certificate

Instructions:  DOC Instructions

  PDF Instructions

Tel: 027-87207771 87207772 87207773 87188862

Verification certificate
Product introduction
SMG3000 Handheld Three-phase Meter is high accuracy, high stability, low power consumption, easy to use. Can test the three-phase AC voltage, current , phase between voltage, phase between current, phase between voltage& current, frequency, phase, active power, reactive power, apparent power, power factor, vector sum when the measurement circuit is not opened. It can also indentify the transformer wiring group, inductive circuit, capacitive circuit, test the secondary circuit and bus bar protection system, read the phase relations of each CT of the differential protection system, check if the ammeter is wiring correctly, check the circuit and equipment. This device applies to electric power, petrochemical corporation, metallurgy, railway, industrial and mining enterprises, research institutions, metrology department, etc, especially applies to power quantity measurement system and relay protection system.
SMG3010 takes single chip as kernel, adopts three separate voltage channels and current channels, large graphics LCD, high-capacity lithium battery, widely used by thousands of customers by its excellent stability, reliability, accurately for long time. It was considered to be classical tester for phase and electric quality.
Alternative name

phase meter, three-phase meter

The Characteristics of the products
SMG3000 Features:
1. Equipped with shock-proof, skid-proof, high insulating protective jacket.
2. Uses 240×160 LCD, dynamic display, vector diagram indicates, easy to read.
3. There are two models current clamp, the cuspate & small ones apply to positions of wire-intensive, the round & big ones apply to test the heavy gage wires. 
4. High precision, high stability, low power consumption. 
5. Safe, accurate, convenient.
SMG3010 Features
1. with seven functions: voltmeter, ammeter, phase meter, phase sequence meter, frequency counter, power meter, power factor meter.
2. Display vector figures with six angles.
3. High precision, can be used as leakage ammeter.
4. Friendly man-machine interface. 
5. long lasting nickel-hydrogen, AC and DC power supply, convenient to field tests. 
6. Serial data interface, can connect with the micro printer and PC. 
7. With LCD(display the data and diagram), convenient to review. 
8. Auto switch the measurement range, soft ware calibrate. 
9. High accuracy clock, battery capacity display 
10. Full digital, high stability 
The parameters of the products

SMG3000  Specification:


category

Measurement range

Resolution

Intrinsic error

voltage

AC 0.00V~600V

0.01V

±(1.5%rdg+3dgt)

current

AC 0.0mA~20.0A

0.1mA

±(1.5%rdg+3dgt)

phase

0.0°~360°

0.1°

±1°

Active power

0.0W~12kW

0.1W

±(3%rdg+3dgt)

Reactive power

0.0VAR~12kVAR

0.1VAR

±(3%rdg+3dgt)

Apparent power

0.0VA~12kVA

0.1VA

±(3%rdg+3dgt)

Frequency  

45HZ~65HZ

0.01HZ

±(2%rdg+3dgt)

Power factor

-1~+1

0.001

±0.03

Note: phase error ±3° under working (phase error ±5° if current amplitude under 10mA).

SMG3010  Specification:
1. measurement range
  (1) phase:0°~360°
  (2) voltage:5~500V
  (3) current:10mA~10A
  (4) frequency:45~65Hz
  (5) power factor:-1~+1
  (6) power:0~2.5KW
2. Intrinsic error
  (1) reference conditions


Temperature

humidity

waveform

frequency

Wire position

Phase angle measurement

voltage

current

20℃±5℃

< 70%

Sine wave distoration≤1%

50Hz±1Hz

geometric center of the jaw

100V±25V

1A±0.2A

  (2) phase:±1°, resolution 0.1°.
      remark: current less than 20mA, relative error less < ±3°.
      voltage:0.5, resolution 0.01V.
      current:0.5, resolution 1mA.
      power factor:1%±2 character
      power:2.0
3. input impedance :1MΩ
4. Working conditions:


temperature

humidity

Phase angle measurement

Voltage amplitude

Current amplitude

0℃-40℃

≤80%

5V-500V

10mA-10A

5. additional error
   (1) the additional error less than intrinsic error when the voltage , current valued under specified operating conditions during the phase measurement.
   (2)the additional error is less than intrinsic error, increased by the wire deviating of the center of the jaw during the current measurement.
6. Voltage withstand and insulation
   voltage withstand:≥100MΩ
   resolution:≥2KV/min, 50Hz sine wave
7. Power supply
  (1) internal battery: long lasting nickel-hydrogen battery, power consumption ≤6W, can use for 16 hours under backlight
  (2) AC power supply: 85-265Vac, 0.8A, power≤8VA


Power supply: AC110V/115V/120V/127V/220V/230V/240V optional
Input frequency: 50Hz/60Hz optional
Note: The users can select the corresponding power which based on their local supply voltage and frequency, and we will confirm it before the delivery (or inform us that the goods will be used in which country advance)