NRCT-400 Multifunction watt-hour Meter Scene Calibrator

NRCT-400 Multifunction watt-hour Meter Scene Calibrator

Classification: Watt-hour Meter Checking/Other Accessories

Reference standard: DL/T826-2002,DL/T448-2002

Verification:  View the certificate

Instructions:  DOC Instructions

  PDF Instructions

Tel: 027-87207771 87207772 87207773 87188862

Verification certificate
Product introduction
NRCT-400 Multifunction watt-hour meter scene calibrator is a a portable device, which specialised in on-site calibration single, three-phase active and reactive power inductive and electronic power meters and many other electrical instrumentation. With precision sampling technique, combined with the latest digital signal processing method, it provides a convenient and efficient solution for on-site calibration meter and many other electrical instrumentations.
Alternative name
Multifunction energy meter field calibrator, meter field calibrator, power meter calibrator, meter tester
The Characteristics of the products
1, Three-phase current, voltage, active power, reactive power, power factor, angle, frequency and other high-precision measurement of electrical parameters.
2, Three-phase active and reactive power inductive, electronic energy meter, and many other electrical instrumentation on-site calibration.
3, The measurement device integrated error-site calibration.
4, The current input terminals and clamp are two ways available, the maximum measurable current 100A.
5, Hexagonal map real-time display, and discrimination based on hexagonal diagram wiring errors, stealing behavior under control.
6, CT ratio precision measurements.
8, 250 to be stored calibration measurement data easily.
9, Large-screen LCD Chinese menu display, a screen displaying all parameters, there are Chinese operation prompt, easy to use.
10, Small size, light weight, beautiful appearance, easy to carry.
The parameters of the products
1, The energy measurement: 0.3
2, AC voltage measurements: (0V-400V) 0.2 级
3, AC current measurements: 0.2
4, Active: 0.3
5, The reactive power: 0.5
6, Frequency Measurement: 45Hz-65Hz (± 0.05Hz)
7, the angle measurement: 0 ° -360 ° (± 1 °)
8, the pulse constant: LF FL = 3200P/kw • h
                     High frequency FH = 3200 × 8P/kw • h
9 Power supply: External power supply: AC220V ± 10%
10, Power consumption: 8VA
11, Working temperature: -10 ℃ -50 ℃
12, Relative humidity: 40% -90%
13, Warm-up time: about 1 minute
14, Size: 37X27X14cm
15, Weight: 3.5KG


Power supply: AC110V/115V/120V/127V/220V/230V/240V optional
Input frequency: 50Hz/60Hz optional
Note: The users can select the corresponding power which based on their local supply voltage and frequency, and we will confirm it before the delivery (or inform us that the goods will be used in which country advance)