BC2000 Insulation Resistance Tester (Two gears)

BC2000 Insulation Resistance Tester (Two gears)

Classification: Earthing/Insulation/SF6 Gas Detection

Reference standard: DL/T845.1-2004,DL/T474.1-2006

Verification:  View the certificate

Instructions:  DOC Instructions

  PDF Instructions

Tel: 027-87207771 87207772 87207773 87188862

Verification certificate
Product introduction
  BC2000 Insulation Resistance Tester (two gears) adopts embedded industrial single-chip Real Time Operating System, adopts extra-thin tensile-spring header perfect assembled with LCD . It with various output voltage (500V,1000V,2500V,5000V), high capacity, strong anti-interference ability, pointer display synchronously with data , applies to DC and AC, easy to operate, calculates the insulating index ( absorptance, polarization index), results automatically, without power failure, etc. It is the ideal equipment to test large-capacity transformer, mutual inductor, generator, HV electric motor, power capacitor, cable, lightning arrester and so on.
Alternative name

 Digital megger pointer megger, insulation sheet, insulation resistance tester, high voltage insulation resistance tester, insulation resistance meter, insulation characteristics tester, high voltage megger, with absorption ratio function megger, with pole index of functional megger, electric shake table, electronic insulation resistance tester, high-power high megger,digital insulation tester,insulation resistance testers,Insulation Tester,Digital High Voltage Insulation Tester,

The Characteristics of the products
1. Kinds of output voltage : BC2000(2500V/5000V), BC2010 (500V/ 1000V/ 2500V/5000V), the measured resistance range 0~200GΩ, auto shift the measurement range, and with corresponding indications. 2. Pointer display synchronously with data display the insulation resistance data. 3. With LCD, auto shift the measurement range. 4. Adopts embedded industrial single-chip Real Time Operating System, high capacity, strong anti-interference ability. 5. Friendly operation interface, results without power failure, can save results of 20 tests. 6. There will be warning tone if the device engender high voltage. 7. Built-in residual HV discharge circuit, can auto discharge the residual high voltage on of the measured equipment after the test. 8. Applies to DC & AC, equipped with rechargeable battery and AC adapter. 9. Portable design, convenient for field tests. 10. HV short circuit current≥3mA, it is the ideal equipment to test large-capacity transformer, mutual inductor, generator, HV electric motor, power capacitor, cable, lightning arrester and so on.
The parameters of the products

model

BC2010


BC2000

Output voltage

500V DC

1000V DC

2500V DC

5000V DC

accuracy

temperature

23℃±5℃

Insulation resistance

1MΩ~20GΩ
±5%

1MΩ~20GΩ
±5%

1MΩ~20GΩ
±5%

1MΩ~20GΩ
±5%

Output voltage

4MΩ~20GΩ
0~+10%

4MΩ~20GΩ
0~+10%

4MΩ~20GΩ
0~+10%

4MΩ~20GΩ
0~+10%

HV short circuit current

≥3mA

Power supply

8 Aatype rechargeable batteries, external rechargeable adapter

Service conditions

Temperature:-10℃~40℃,relative humidity 85%

Storage conditions

Temperature:-20℃~60℃,relative humidity <=90%

Insulating property

If the voltage between circuit and shell is 1000 DC, Max.2000MΩ

Withstand voltage properties

If the voltage between circuit and shell is 2500V AC, stand 1min

size

230mm×190mm×90mm  (L×W×H)

weight

2KG

accessories

Wire, instrction manual,certificate,rechargeable adapter,power cord


Power supply: AC110V/115V/120V/127V/220V/230V/240V optional
Input frequency: 50Hz/60Hz optional
Note: The users can select the corresponding power which based on their local supply voltage and frequency, and we will confirm it before the delivery (or inform us that the goods will be used in which country advance)